Like the T series, but with a heating surface either in the form of a heating jacket or a coil. Combined with a mixer/scraper whose function is to keep the heat exchanger permanently clean as far as possible. Concentrate is removed through a flap in the floor; the mixer assists the removal.


  FEATURES:

    The features of the T series plus the following:
 - The installed mixer/scraper keeps the heating surface of the heat exchanger permanently clean, which     means that greater concentrations of uniform consistency can be achived.
 - The version with coil instead of heating jacket permits energy cunsumption of only approx. 100 W/l instead     of approx. 200 W/l (depending on system size)  
 - On request, automatic emptying by means of a motorised floor flap is available  
 - Non-stick and corrosion-proof coatings (Teflon, Halar...) are also available.